Midterm Outcomes of Four-Corner Fusion Surgery Using Nitinol Staples.

Ahmady AA, Zalzaleh M, Riedel BB

ManuscriptManuscript

Publication record

Journal of hand surgery global online

Ahmady AA; Zalzaleh M; Riedel BB. Midterm Outcomes of Four-Corner Fusion Surgery Using Nitinol Staples. Journal of hand surgery global online. 2025;7(5):100805. https://doi.org/10.1016/j.jhsg.2025.100805 Abstract reproduced from https://www.ebi.ac.uk/europepmc/webservices/rest/PMC12351334/fullTextXML. License: http://creativecommons.org/licenses/by/4.0/.

Abstract

Purpose Wrist arthritis because of scaphoid nonunion advanced collapseand scapholunate advanced collapse can be treated through scaphoid excision and four-corner arthrodesis. There are many fixation techniques; however, there are few studies reporting outcomes in which only Nitinol staples were used. This study aimed to evaluate whether patients undergoing a four-corner arthrodesis using this fixation technique as well as intraoperative modifications to minimize complications will have successful outcomes. Methods Retrospective study of patients who underwent scaphoid excision and four-corner arthrodesis using DynaNite Nitinol Staple (Arthrex Inc) to treat scaphoid nonunion advanced collapse or scapholunate advanced collapse wrist arthritis at a single academic institution by a single surgeon. The technique and our modifications are described below. Outcome measures included radiographic union, range of motion, strength, and patient-reported outcomes such as Quick Disabilities of the Arm, Shoulder, and Hand, Michigan Hand Outcomes questionnaire, Likert patient satisfaction scale, and the visual analog scale. Results Eight patients were included with mean follow-up of 27 months (9–42 months). When compared to the contralateral side, patients maintained 76% wrist flexion-extension, 83% radial-ulnar deviation, and 99% pronation-supination. Key pinch, three-point pinch, and grip strength testing were 95%, 89%, and 86%, respectively. The mean Quick Disabilities of the Arm, Shoulder, and Hand score was 17, and the mean Michigan Hand Outcomes score was 85% compared to the contralateral side. The visual analog pain scale had a mean of 2.5 (range 0–6). Radiographic imaging showed that all patients had undergone union of their four-corner arthrodesis with intact hardware. Conclusions The results of this study show that midterm outcomes of four-corner fusions performed with Nitinol staples have promising results in overall functional and patient-reported outcomes. In addition, they offer reliable fixation for achieving union of the four-corner arthrodesis. Type of study/level of evidence Therapeutic IV.